FM-16-9, Fiber Optical Multiplexer

Specification:
Optical Fiber Interface Source: MLM Laser
Wavelength: 1310 ± 50 nm, 1550 ± 40 nm
Power: -26 or -8 dBm
Receiver Sensitivity: -38 dBm at BER < 10-10
50 Km reach
System Gain: 30 dB
Line Code: Scrambled NRZ
Detector Type: PIN-FET
Fiber Type: Single mode
Protection: Optional 1+1 APS
NOTE: Longer or shorter, 15 to 120Km, on special order.
E1 Line Interface Number of E1 lines: Up to 16
Line Rate: 2.048 Mbps ± 50 ppm
Line Code: HDB3
Line Impedance: 120W twisted pair, 75W for BNC
Connector: RJ48C, BNC, DB37
Output Signal: ITU G.703
NOTE: Other Impedance, 100W and 110W, on special order.
Bridge 10/ 100 Mbps half/ full duplex ethernet bridging and 100 Mbps operation on the HDLC port
ANSI/ IEEE Std. 802.1D MAC Bridging capabilities (without spanning tree algorithm)
Automatic MAC table learning and aging
Support VLAN and extended Ethernet frame support
4-RS232 Connector: DB25
Data Rate: Up to 64Kbps async
V.35 Port Number: 4 ports
Data Rate: Nx64kbps (N=1~32)
Connector: M34
Clock Mode: External, Internal, Received (Selectable); DTE/DCE programmable
SNMP Port Connector: RJ45 at rear panel
Protocol: Telnet
Console Connector: DB9 at front panel
Electrical: RS232 interface
Protocol: Menu driven VT-100 terminal
Baud Rate: 9600, 19200, 38400, 57600, 115200
Switches and Contacts Power, Alarm Cut-Off, Reset, A & B dip switches for command setup, and ENTER for command execute.
Major and Minor alarm contact closures, DB9F connector.
Indicators Power, Major & Minor Alarms, System Fail, Abnormal Operation, Electrical Failure.
Receive signal indications for all E1s.
Local optical signal receive indication, working and protection.
Remote optical signal receive indication, working and protection.
Laser operation, working and protection.
Command execution complete.
Physical/Electrical Dimensions for 1U: 44 x 432 x 255 mm (HxWxD)
Dimensions for 2U: 88 x 432 x 255 mm (HxWxD)
Dimensions for 3U: 132 x 432 x 255 mm (HxWxD)
Mounting: Stand-alone, 19 or 23 inch rack mount
Power Source: -42 to -60 Vdc or 100 to 240 Vac, 50/ 60 Hz
Power Protection: Optional 1+1 APS
Power Consumption: < 30 W
Temperature Range: 0oC to 50oC
Humidity: 0% — 95% RH (non-condensing)
Diagnostics Test Optical Fiber: Local and remote loopbacks
E1 Lines: Local and remote loopbacks
Applications: